GP107 - Overload System, Load Cell Based
Product Highlights
The GP107 control module
is designed to prevent vehicle movement when platform overload is
detected. The module interfaces with two or four strain gauge/ load cell
transducers to measure the load of the work platform.
The GP107 can also be used for measuring the load on the forks of a
telescopic handler to prevent vehicle tipping.
- Provides cutout signal when overloaded (per EN 280 5.4.1.2a) using 1 or more load cell (basket rotator ring, load pins, Cantilever/ Shear Beam or Strain Gauges)
- Configurable lamp & alarm output (per EN 280 5.4.1.2b)
- Overload cutout can be disabled when driving, steering, etc to avoid nuisance shutdowns
- Interlocks (subject to installation, per EN 280 5.4.1.2c and EN 280 5.7.7)
- RS232 connection to hand-held “EZcal” for
calibration and diagnostics
Technical Data:
| Power Supply | 12/24V |
| Failsafe High Side Cutout Output, protected, 2.5A | 1 |
| High side Indicator Output, protected 1A | 3 |
| Integral Tilt Sensor | ± 0 to 10° |
| Digital Inputs | 8 |
| Analog Inputs | 2 |
| Diff. Analog Inputs | 4 |
| Sealing | IP67 |
| Operating Temperature | -40 + 60° C |
| Overall Dimensions, L x W x H | 7.3” x 4.5” x 1.5” 185 x 115 x 39 mm |


specifications