| (after warm-up time at 25 °C) | |
| Regulation | |
| - load variation 10-90 % static | typ. 0,5%(max.1,0%) |
| dynamic | typ. 1,0%(max.2,0%) |
| - input voltage variation +/-10% | typ. 0,2%(max.0,5%) |
| Recovery time to ±1% | typ. 0,25ms (max.0,5ms) |
| Efficiency at full load | |
| - typ. with 13,8V output | typ. 86% |
| - typ. with 26V output | typ. 87% |
| Ripple and noise | 1,5% U-out NOM |
| Switching spikes | typ. 100mVpp |
| Conducted interference at input | ≤ 1% pp.max |
| Idle current input at 72VDC | ca./approx. 15mA |
| Ambient temperatures | |
| - storage temperature range | -40°C...+105°C |
| - operating temperature range | -40°C...+105°C |
| - operating temperature range at full load | -40°C...+70°C |
| (temperature at heat sink) | |
| - temperature coefficient | coefficient 0,05% / °K |
| Humidity | 100 % RH |
| Switching frequency | typ. 110 kHz |
| Break down voltage input/output | 1000 VDC / 1 min. |
| Isolated resistance | 100 MΩ |
| Output short circuit protected by switch off | ca. 120 % I-nom |